• Users Online: 99
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2020  |  Volume : 10  |  Issue : 4  |  Page : 275-285

Radiographic texture reproducibility: The impact of different materials, their arrangement, and focal spot size


1 Student Research Committee, School of Allied Medicine, Kerman University of Medical Sciences, Kerman, Iran
2 Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland
3 Department of Biomedical and Health Informatics, Rajaiee Cardiovascular Medical and Research Center, Iran University of Medical Science, Tehran, Iran
4 Department of Medical Biotechnology, School of Paramedical Sciences, Qazvin University of Medical Sciences, Qazvin, Iran
5 Department of Emergency Medicine, School of Medicine, Kerman University of Medical Sciences, Kerman, Iran
6 Student Research Committee, School of Allied Medicine; Department of Radiologic Sciences and Medical Physics, Faculty of Allied Medicine, Kerman University of Medical Sciences, Kerman, Iran

Correspondence Address:
Dr. Hamid Abdollahi
Department of Radiologic Sciences and Medical Physics, Faculty of Allied Medicine, Kerman University of Medical Sciences, Medical University Campus, Haft-Bagh Highway, Kerman
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmss.JMSS_64_19

Rights and Permissions

Background: Feature reproducibility is a critical issue in quantitative radiomic studies. The aim of this study is to assess how radiographic radiomic textures behave against changes in phantom materials, their arrangements, and focal spot size. Method: A phantom with detachable parts was made using wood, sponge, Plexiglas, and rubber. Each material had 1 cm thickness and was imaged for consecutive time. The phantom also was imaged by change in the arrangement of its materials. Imaging was done with two focal spot sizes including 0.6 and 1.2 mm. All images were acquired with a digital radiography machine. Several texture features were extracted from the same size region of interest in all images. To assess reproducibility, coefficient of variation (COV), intraclass correlation coefficient (ICC), and Bland–Altman tests were used. Results: Results show that 59%, 50%, and 4.5% of all features are most reproducible (COV ≤5%) against change in focal spot size, material arrangements, and phantom's materials, respectively. Results on Bland–Altman analysis showed that there is just a nonreproducible feature against change in the focal spot size. On the ICC results, we observed that the ICCs for more features are >0.90 and there were few features with ICC lower than 0.90. Conclusion: We showed that radiomic textures are vulnerable against changes in materials, arrangement, and different focal spot sizes. These results suggest that a careful analysis of the effects of these parameters is essential before any radiomic clinical application.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed86    
    Printed2    
    Emailed0    
    PDF Downloaded13    
    Comments [Add]    

Recommend this journal